- Joe Kerwin (CAPCOM)
-
Roger. And, on panel 275, we want all the circuit breakers open; no exceptions. Over.
- Joe Kerwin (CAPCOM)
-
Okay, and that's all for page 1-10. You want to read any of that back? I think you've got it all.
- Joe Kerwin (CAPCOM)
-
Okay. Let's go to page 1-11. On panel 276, no change; on panel 278, we want all circuit breakers open; no exceptions. Over.
- Joe Kerwin (CAPCOM)
-
Roger. Now we'll skip all the way down to panel 306 where we want the MISSION TIMER to STOP and the EVENT TIMER to STOP. Over.
- Joe Kerwin (CAPCOM)
-
Okay. On page 1-12, panel 325, we want both CABIN PRESSURE RELIEF valves to NORMAL. Over.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 326, we want the REPRESS PACKAGE valves to OFF; the SM O2 SUPPLY valves to OFF; the SURGE TANK O2 valve to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Roger. You did include the REPRESS PACKAGE there. Okay, GLYCOL RESERVOIR IN valve to CLOSED. BYPASS to OPEN, and OUT valve to CLOSED. Over.
- Jack Swigert (CMP)
-
Okay. GLYCOL RESERVOIR IN valve CLOSED; BYPASS valve OPEN; and RESERVOIR OUT valve CLOSED.
- Joe Kerwin (CAPCOM)
-
That's affirmative. Panel 350, no change. Panel 351, MAIN REGULATOR valves, two, to CLOSED, and the H2O/GLYCOL TANK PRESSURE REGULATOR valve, OFF, and RELIEF valve, OFF. Over.
- Jack Swigert (CMP)
-
Okay. MAIN REG valve, two, to CLOSED. WATER/GLYCOL TANK PRESSURE REG and RELIEF valves, both OFF.
- Joe Kerwin (CAPCOM)
-
Okay. Go down to panel 380, O2 DEMAND REG valve, OFF, and SUIT CIRCUIT RETURN VALVE, pulled to OPEN. Over.
- Jack Swigert (CMP)
-
Okay, both O2 DEMAND REG valves are OFF and SUIT CIRCUIT RETURN VALVE pulled OPEN.
- Joe Kerwin (CAPCOM)
-
That's correct. Go to panel 382. The first one, two, three, four are unchanged. We want SEC EVAP H2O CONTROL valve OFF, and PRIM EVAP H2O CONTROL valve to OFF. Those both are both counterclockwise. Over.
- Jack Swigert (CMP)
-
Okay, Houston. Reading back 382, SECONDARY EVAPORATOR H2O CONTROL valve's OFF, and PRIMARY EVAPORATOR H2O CONTROL valve, OFF.
- Joe Kerwin (CAPCOM)
-
That's correct. Those are the only changes on 1-13, and there are no changes on 1-14, and you've got it all, Jack. Over.
- Joe Kerwin (CAPCOM)
-
Okay. You can get those configures when you can. And the next order of business I've got for you is a procedure to verify that MAIN BUS B is good. And a little after that, we'll want to read up to you, for your future information, a procedure for transferring LM power to the command module. Over.
- Jack Swigert (CMP)
-
Okay. That sounds good. You want to get this PLSS configuration done first before you give those other procedures, huh?
- Joe Kerwin (CAPCOM)
-
Yes, I think so. Stand by 1 second and I'll see if FLIGHT has any words for us before you start that.
- Joe Kerwin (CAPCOM)
-
Okay, we don't have anything for you. Our only concern is that you'll wake up somebody; is there anybody sleeping right now?
- Jack Swigert (CMP)
-
No. We're all sitting here eating. I'm just going to get a bite to eat. Then I'll write down that switch configuration, or I'll copy the procedure now, if you want.
- Joe Kerwin (CAPCOM)
-
Yes, okay. Understand they are all up. Did you say you wanted to copy the other procedure now? Over.
- Jack Swigert (CMP)
-
I'll tell you, I'll get my switch set done first before I eat so I won't disturb Jim any.
- Joe Kerwin (CAPCOM)
-
Stand by 1 minute, Jack, before you go in there. FLIGHT has got one other item for you.
- Jack Swigert (CMP)
-
You know what I thought—I think what we saw venting was the result of our DELTA-Vs stirring up things, popping the relief valve. Yes. We don't see anything venting now. …
- Jack Swigert (CMP)
-
Okay, Houston. We are standing by.
Expand selection up Contract selection down Close - Joe Kerwin (CAPCOM)
-
Okay, Jack. You can go ahead and set up that switch configuration. What we are discussing is having you activate the MAIN BUS TIE motor switches a little later on simply to verify that they will be okay, because the batteries are probably getting a little bit cool. But we'll be back to you with a procedure and discussion about that after you get the switch configuration set up. Over.
- Jack Swigert (CMP)
-
Okay, I'm going to go get the switch configuration done now before Jim goes to bed so I don't disturb him.
- Jim Lovell (CDR)
-
Okay, before I hit the sack, Joe, I just want to make sure—How are you still planning an MCC at 107 and what's the latest find?
- Joe Kerwin (CAPCOM)
-
Okay, Jim. We are still gathering our thoughts on the MCC, but some of the considerations go like this: FIDO tells us that we can do that correction probably as late as 118 hours, with no significant DELTA-V penalty, and with plenty of tracking thereafter to make sure that we've done the right thing, and to set you up for a late MCC if we need it, which we probably wouldn't. We are happy with the PTC mode that you are in now, and, although we are working up a—an AGS PTC mode to use after the midcourse correction, we'd kind of like you to stay in this PTC for a while because it is doing good. We are looking at the weather in the landing area. We don't think we'll have a problem but we are checking it real close, and if there is any changing that we want to do, we want to get it into this midcourse correction. And for reasons like that, we are considering possibly delaying the midcourse correction from 104 hours to some time between there and 118. We'd like to know what you think about it. Over.
- Jim Lovell (CDR)
-
We have no druthers. As long as we do the midcourse and there is plenty of tracking thereafter to correct for another midcourse; that's my only concern.
- Joe Kerwin (CAPCOM)
-
Okay, Jim. Roger that. And based on FIDO's input that he'd like to do it not later than 24 hours before EI, we will be doing it prior to 118 hours.
- Fred Haise (LMP)
-
Question, Joe. Jim has been talking to me about how we are going to do this midcourse, and awhile back when we went through this power up, we had pulled the STAB/CONTROL ASA breaker. I was wondering—we lost the heaters in the ASA—I was wondering how it looked? What kind of shape it's going to be in?
- Joe Kerwin (CAPCOM)
-
Roger. I am told that we'd see 38 degrees for that package, and it'll be okay for the burn. We're massaging the detail procedures for this burn at this time and we expect to have a real clean setup to you in plenty of time.
- Fred Haise (LMP)
-
And I don't know if Jack passed it on to you, but Jack and I just finished logging about 6 hours sleep, each.
- Fred Haise (LMP)
-
Yes. We made the mistake of putting up the window shades, which we won't do again; and with this powered-down mode, we're not generating much internally, and it really did get chilly.
- Joe Kerwin (CAPCOM)
-
Yes. I guess you'll have to generate your own heat in there for a while.
Expand selection down Contract selection up - Joe Kerwin (CAPCOM)
-
Fred, just wanted to let you know in advance that we're coming up on the redline CO2 value for the secondary canister, and we expect to get there in something like a half hour, at which time we'll be asking you to switch over to the command module canisters. I have the rest of that procedure ready and I just wanted to warn you a little bit in advance. Over.
- Fred Haise (LMP)
-
Okay. The—I need to find out if the condensate container that we were going to use to strain some water in on the lunar surface—is that container also completely airtight? Okay to use it to put fluid in through here in zero g?
- Joe Kerwin (CAPCOM)
-
Fred, Houston. We'll have to stand by for 1 minute. We are in a noisy state of COMM.
- Fred Haise (LMP)
-
Okay. I was just going to say we haven't had an overboard waste water dump since clear back around the other side of the Moon. About this time, we're running out of the bags we've got on board here.
- Joe Kerwin (CAPCOM)
-
Okay. I'm—I'm stupid this morning, Fred. I'm not quite sure what you are getting at.
- Joe Kerwin (CAPCOM)
-
Okay. It sounds to me as if the suggested receptacle is perfectly satisfactory. Do you think you can use it in its present configuration?
- Fred Haise (LMP)
-
Oh, yes. We got all the innerconnects—hookups we need, but I wasn't sure if that gadget was devised solely with the 1/6g environment in mind, and whether it might leak somehow in zero g.
- Joe Kerwin (CAPCOM)
-
I'll have them verify that, but off the top of my head, I'm sure it's going to be all right. We'll check it, Fred.
Spoken on April 15, 1970, 3:57 p.m. UTC (54 years, 6 months ago). Link to this transcript range is: Tweet