- Fred Haise (LMP)
-
Okay, Joe. One thing I've noticed, that a couple of circuits there now—the pulse …—at least the number of them, is markedly decreased, and … rather bad and, apparently, that added venting we had out of the service module was some overboard relief valve, maybe letting go, because it appears to have stopped now.
- Fred Haise (LMP)
-
I'm reading about 12.5. I guess we've got a gage problem … I did just get a MASTER ALARM and no caution light; we kind of figured that's what it was, with CO2 approaching its limit. Maybe it didn't quite come out here.
- Joe Kerwin (CAPCOM)
-
Okay. Let me get a go, and I think it's time for us to go ahead and put these other canisters on. Stand by 1.
- Fred Haise (LMP)
-
— I don't have a steady—I don't have a steady ECS light on at this time, Joe, so it must have just been a momentary.
- Joe Kerwin (CAPCOM)
-
Okay. We know when you went to 15 last night on primary. We want to switch out today at 7.6. Let me check and see if we're ready.
- Fred Haise (LMP)
-
Okay. I was just—I'm getting MASTER ALARMS every few seconds and I am catching a glimmer now of the ECS light. For the time being, I have …—… open. Okay, now we got the ECS light on steady.
- Joe Kerwin (CAPCOM)
-
Okay. Copy that. You have the MASTER ALARM, with the ECS light. We are ready to go ahead and get you on the command module canisters. And as the first step, I'd like to know whether you've inserted the commander's red hose to the second canister bag. Over.
- Fred Haise (LMP)
-
Okay. Yes. Sure enough; the commander's red hose is inserted into the canister bag.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. The next thing I'd like you to do is to take some more gray tape and tape over half the outlet area of each of the blue nozzles; the commander's and the LMP's. The reason we're doing this is we're going to be running this loop through the secondary LiOH canister hole with the canister removed, and we don't have the flow restriction we need to keep the separator from overspeeding. Over.
- Fred Haise (LMP)
-
Okay. Yes, that's right. So we want to tape over half of the—both the blue and the red commander hoses. Is that right?
- Joe Kerwin (CAPCOM)
-
Negative, Fred. That's half of the commander's blue hose and half of the LMP's blue hose—the outlet hoses.
- Fred Haise (LMP)
-
Okay. I'm going to turn off one suit flow valve at a time while I am doing the taping, Joe.
- Fred Haise (LMP)
-
Okay, while I'm doing the taping, I'll have that particular suit flow valve in the suit DISCONNECT position momentarily.
- Fred Haise (LMP)
-
Okay. One correction—the red hose that's connected up right now to the lithium cartridge in the LMP's—Wait a minute.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. Understand only the LMP's red hose is actually plugged into the canister bag. In that case, we would like you to follow the procedure for inserting the other red hose in the other canister bag as follows: you cut a diagonal hole in one corner of the bag. Look at the other bag and see how it was done. Stick the hose in about 6 inches. Try to get the outlet nozzle down if you can, or else sideways, and then just tape up the hose to the bag to make a nice tight seal. Over.
- Fred Haise (LMP)
-
No. That's still in works. I just wanted to comment you might pass on to Steve Grega, we thank you a lot for those rendezvous procedures. They went to making up these little boxes.
- Joe Kerwin (CAPCOM)
-
Okay. We appreciate your appreciating it. We're just having a ball down here working on all kinds of new procedures, Fred. The CPCB is in session, and we expect to have your entry procedures out here by Saturday or Sunday at the very latest.
- Fred Haise (LMP)
-
Okay. Back to the condensate container. I guess the only question I really need answered is will it leak?
- Fred Haise (LMP)
-
And we've checked all the fittings and I know I can hook everything up to our UCDs. So, if it doesn't leak, we can transfer.
Expand selection up Expand selection down Close
Spoken on April 15, 1970, 5:05 p.m. UTC (54 years, 7 months ago). Link to this transcript range is: Tweet